Specifications |
Model# |
|
SRIC-4 |
Measurement Range |
|
-25°C ~ +60°C (-13°F ~ +140°F)
|
Resolution |
|
<
0.1°C/°F |
Accuracy |
|
±0.5°C (±0.9°F) or better for measurements from -5°C ~ +30°C (23°F ~ +86°F),
±0.8°C (±1.5°F) or better for measurements in other areas of rated range . |
Sensor
reaction time |
|
typically
less than 5 minutes(T90) in moving air (1m/s). |
Capacity |
|
3968 logs (i.e 13.75 days @ 5min logging, 41.25 days @ 15min logging and 82.5days @ 30 min logging.)
|
Sampling
frequency |
|
adjustable, 1~60 minutes or 1~18 hours |
Logging start options |
|
Push button start or specific date & time. |
Recording
indication |
|
Flashing
'OK' indicator flashing 'Alert' indicator. |
Download
Time |
|
Typically
with full memory (3968 readings) in less than 4 secs depending on computer
or readout device used. |
Environmental |
|
IP65 (roughly equivalent to NEMA 4) |
Power
source |
|
3V
Lithium battery |
Battery
life |
|
Projected life of 6 months of operation from time of configuration.
Shelf life before configuration of up to 2 years. |
Size |
|
77mm(H)x54.5mm(W)x8.6mm(T) |
Weight |
|
28g |
Case
Material |
|
Polycarbonate |
Other
features |
|
Optional
clearing of alert indication by push button (places inspection make at same
time).
Download
inspection mark recorded in LogTag memory every time LogTag is downloaded.
'Prestart'
fail-safe logging (records temperature data even if not started)
Low
Battery indication in software.
Comprehensive Alert indicator configuration.
Calibration
to achieve higher accuracy possible.
|
Note: Resolution &
Accuracy are rated values - actual product performance may be substantially
better than figures stated. |